Login / Signup

Utilization of 3-T fetal magnetic resonance imaging in clinical practice: a single-institution experience.

Usha D NagarajMaria A Calvo-GarciaA Carl MerrowBin ZhangJean A TkachBeth M Kline-Fath
Published in: Pediatric radiology (2021)
While 3 T is a feasible alternative to 1.5 T for fetal MRI, the increased artifacts and longer exam times observed at 3 T without clear improvement in overall image quality make 1.5 T preferable for fetal MRI in routine clinical practice.
Keyphrases
  • clinical practice
  • image quality
  • contrast enhanced
  • magnetic resonance imaging
  • computed tomography
  • diffusion weighted imaging
  • magnetic resonance