A comparison of three techniques for the osteosynthesis after minimal invasive osteotomies for hallux valgus.
Abraham Guadalupe Espinosa-UribeFernando A Fernández-GarzaDavid Muñoz-LeijaJosé Félix Vílchez-CavazosAlejandro Quiroga-GarzaVíctor M Peña-MartínezRodrigo E Elizondo-OmañaJorge Gutiérrez-de la OPublished in: International orthopaedics (2024)
The K-wire first technique statistically significantly decreases X-ray IS numbers p ≤ 0.001. There were no statistically significant differences between the traditional (after osteotomy K-wire placement) and the drill and joystick techniques (p = 0.36).