Login / Signup

Bio-Specific Au/Fe3+ Porous Spongy Nanoclusters for Sensitive SERS Detection of Escherichia coli O157:H7.

Yuzhi LiFei GaoChang LuMarie Laure FauconnierJinkai Zheng
Published in: Biosensors (2021)
For sensitive and fast detection of Escherichia coli O157:H7, organic and inorganic hybrid Au/Fe3+ nanoclusters (NCs) were synthesized for the first time using gold nanoparticles (GNPs), bovine serum albumin, ferric chloride, phosphate-buffered saline, and antibodies. The Au/Fe3+ porous spongy NCs with large surface area showed excellent bio-specific capability for E. coli O157:H7. GNPs in Au/Fe3+ NCs functioned as signal enhancers, significantly increasing the Raman signal via the metathesis reaction product of Prussian blue and obviously improving the detection sensitivity. We combined the novel Au/Fe3+ NCs with antibody-modified magnetic nanoparticles to create a biosensor capable of sensitive detection of E. coli O157:H7, which showed a good linear response (101 to 106 cfu/mL), high detection sensitivity (2 cfu/mL), and good recovery rate (93.60-97.50%) in spiked food samples. These results make the biosensor well-suited for food safety monitoring. This strategy achieves the goal of sensitive and quantitative detection of E. coli O157:H7.