Reliability of glomerular filtration rate estimating formulas compared to iohexol plasma clearance in critically ill children.

Evelyn DhontCharlotte WindelsEvelien SnauwaertTatjana Van Der HeggenAnnick de JaegerLaura DhondtJoris DelangheSiska CroubelsJohan Vande WallePeter De PaepePieter A De Cock
Published in: European journal of pediatrics (2022)
• eGFR formulas were found to be largely inaccurate in the PICU population when compared to measured GFR by iohexol clearance. Clinicians should therefore use these formulas with caution to guide drug dosing and therapeutic interventions in critically ill children. • Iohexol plasma clearance could be considered an alternative for accurate GFR assessment in PICU patients.