A cadaveric study of the three different palpation-guided techniques for glenohumeral joint injections.
Paul BorbasKarim EidEugene T EkMatthew RicksGeorg FeiglJulian M JeserschekPublished in: Shoulder & elbow (2019)
Use of a superior approach through the Neviaser portal for the palpation-guided technique for glenohumeral joint injections showed a statistically significant inferior accuracy when compared to both the posterior and anterior approaches and is therefore not recommended. Posterior approached injections were the most accurate.