Effect of Different Surface Treatments on Titanium Dental Implant Micro-Morphology.
Gaetano MarenziFilomena ImperoFabio ScherilloJosè Camilla SammartinoAntonino SquillaceGianrico SpagnuoloPublished in: Materials (Basel, Switzerland) (2019)
The examined implant surfaces showed different roughness levels in relation to the superficial treatment applied. The acid-etched surfaces were characterized by the presence of deeper valleys and higher peaks than the sandblasted surfaces. For this reason, acid-etched surfaces can be more easily damaged by the stress produced by the peri-implant bone during surgical implant placement.