The Significance of FilmArray Blood Culture Identification Panel (FA-BCID) for Managing Patients with Positive Blood Cultures.

Kristin WidyasariSeung Jun LeeOh-Hyun ChoSun-In HongByung-Han RyuSunjoo Kim
Published in: Diagnostics (Basel, Switzerland) (2023)
We analyzed the accuracy and time efficiency of the FilmArray blood culture identification (FA-BCID) panel in identifying the pathogens in positive blood cultures. Two-hundred and seventy-two individuals were randomly assigned as the control ( n = 212) and FA-BCID ( n = 60) groups participating in this study. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was used to assess the control group. Meanwhile, the FA-BCID group was evaluated using both FA-BCID and MALDI-TOF, and the results were compared. The identification results from 73% (44/60) of the blood samples demonstrated agreement between FA-BCID and MALDI-TOF. The FA-BCID panel detected mecA genes in seven Staphylococcus species; six cases were confirmed using antimicrobial susceptibility testing. In addition, KPC genes were detected in one Escherichia coli and one Klebsiella pneumoniae , although only the latter corresponded with the result from antimicrobial susceptibility testing. The turnaround time (TAT) for identification through FA-BCID was shorter, with a median of 3.6 [2.4-4.6] hours ( p < 0.05). No significant differences in the clinical and microbial outcomes following the ASP were observed between FA-BCID and MALDI-TOF. These results suggest that the FA-BCID panel provides an identification result that is as reliable as that provided by the routine identification procedure but with shorter TAT; thus, the FA-BCID method is considered an effective and beneficial method for therapeutic decision making and the improvement of the ASP for patients with bloodstream infection.
Keyphrases