Regional differences in the effects of the ablation index and interlesion distance on acute electrical reconnections after pulmonary vein isolation.
Kyoichiro YazakiKoichiro EjimaSatoshi HiguchiDaigo YagishitaShohei KataokaNobuhisa HagiwaraPublished in: Journal of arrhythmia (2020)
Smaller ILD may prevent acute PVRs when the AI min is low in the left posterior segments.