Login / Signup

Comparison of perfusion signal acquired by arterial spin labeling-prepared intravoxel incoherent motion (IVIM) MRI and conventional IVIM MRI to unravel the origin of the IVIM signal.

Xingxing ZhangCarson IngoWouter M TeeuwisseZhensen ChenMatthias J P van Osch
Published in: Magnetic resonance in medicine (2017)
This study showed much more complicated diffusion properties of vascular signal than the conventionally assumed single D* of the perfusion compartment in the two-compartment model of IVIM (biexponential behavior). Magn Reson Med 79:723-729, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Keyphrases
  • contrast enhanced
  • diffusion weighted imaging
  • magnetic resonance
  • diffusion weighted
  • magnetic resonance imaging
  • computed tomography
  • room temperature
  • high resolution
  • mass spectrometry