Login / Signup

High Hemoglobin Is an Independent Risk Factor for the Development of Hemolysis During Pediatric Extracorporeal Life Support.

Christopher L JenksAyesha ZiaRamgopal VenkataramanLakshmi Raman
Published in: Journal of intensive care medicine (2017)
An Hb level greater than 13 g/dL was associated with an increased risk of hemolysis, and a high Hb on a given day was associated with a significantly higher risk of hemolysis on the same day. Higher RPMs and lower inlet venous pressures were associated with an increased risk of hemolysis in the centrifugal pump only.
Keyphrases
  • red blood cell
  • young adults