An Electroanalytical Solution for the Determination of Pb 2+ in Progressive Hair Dyes Using the Cork-Graphite Sensor.
Thalita Medeiros BarrosDanyelle Medeiros de AraújoAlana Tamires Lemos de MeloCarlos Alberto Martínez-HuitleMarco VoccianteSergio FerroElisama V Dos SantosPublished in: Sensors (Basel, Switzerland) (2022)
Lead is one of the most toxic metals for living organisms: once absorbed by soft tissues, it is capable of triggering various pathologies, subsequently bioaccumulating in the bones. In consideration of this, its detection and quantification in products for human consumption and use is of great interest, especially if the procedure can be carried out in an easy, reproducible and economical way. This work presents the results of the electroanalytical determination of lead in three different commercial products used as progressive hair dyes. Analyses were performed by cyclic voltammetry (CV) and differential pulse stripping voltammetry (DPSV) using a composite cork-graphite sensor in 0.5M H 2 SO 4 solution or 0.1M acetate buffer (pH 4.5), in the presence and absence of hair dye samples. The H 2 SO 4 solution gave better results in terms of analyte sensitivity than the acetate buffer electrolyte. In both cases, well-defined signals for lead were obtained by DPSV analyses, enabling the calibration curve and figures of merit to be determined. The limits of detection (LOD) were found to be approximately 1.06 µM and 1.26 µM in H 2 SO 4 and acetate buffer, respectively. The DPSV standard addition method was successfully applied to quantify the lead in hair dye samples, yielding values below 0.45% in Pb. All three analyzed samples were shown to comply with the limit set by the Brazilian Health Regulatory Agency, i.e., 0.6% lead in this type of product. The comparison of the electroanalytical results with those obtained by the reference method, based on the use of inductively coupled plasma optical emission spectrometry (ICP-OES), confirmed that the electroanalytical detection approach is potentially applicable as a strategy for quality control.
Keyphrases
- quality control
- aqueous solution
- multiple sclerosis
- loop mediated isothermal amplification
- high resolution
- real time pcr
- heavy metals
- healthcare
- solid phase extraction
- public health
- solid state
- label free
- gene expression
- mental health
- transcription factor
- molecularly imprinted
- ionic liquid
- risk assessment
- health risk
- high speed
- drinking water
- gram negative
- social media
- simultaneous determination