Associations between insulin pump self-management and HbA1c in type 1 diabetes.
Karen RytterKristoffer Panduro MadsenHenrik Ullits AndersenEva HommelUlrik Pedersen-BjergaardSigne SchmidtKirsten NørgaardPublished in: Diabetic medicine : a journal of the British Diabetic Association (2023)
Self-adjusting insulin pump settings, optimal timing and few omissions of meal boluses, and timely change of infusion set are associated with lower HbA1c.