Login / Signup

Radioiodine-131 Therapy Used for Differentiated Thyroid Cancer Can Impair Titanium Dental Implants: An In Vitro Analysis.

Doina PiciuSimion BranMărioara MoldovanSimona VarvaraAndra MesterMariana PacurarCristina Moisescu-GoiaElena BarbusAlexandru MesterFlorin Gligor Onisor
Published in: Cancers (2023)
After exposure to I-131, the structure of titanium implants is well preserved up to 12 h. The eroded particles start to appear in the microstructural details after 24 h of exposure and their numbers progressively increase up to 384 h after exposure.
Keyphrases
  • white matter
  • multiple sclerosis
  • stem cells