Determination and verification of reference intervals of serum immunoglobulin G at birth.

Toshihiko IkutaSota IwataniSeiji Yoshimoto
Published in: Annals of clinical biochemistry (2023)
We established GA-/BW-dependent reference percentile-based intervals for serum IgG levels using cord blood from 2,902 newborns without congenital disorders. Using GA-dependent reference intervals may be useful for assessing hypogammaglobulinemia at birth.
Keyphrases
  • cord blood
  • pet ct
  • gestational age
  • pregnant women
  • mass spectrometry
  • solid phase extraction
  • molecularly imprinted