Login / Signup

The relationship between coronary stent strut thickness and the incidences of clinical outcomes after drug-eluting stent implantation: A systematic review and meta-regression analysis.

Akira SaitoZhehao DaiMasafumi OnoTakayoshi KanieYoshimitsu TakaokaAtsushi MizunoNobuyuki KomiyamaTaku Asano
Published in: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2021)
In this meta-regression analysis, a thinner strut thickness was associated with reduced incidences of early stent-related adverse events (1-year TLR, PMI, and early ST), but not with later events (5-year TLR, late ST, and very late ST).
Keyphrases
  • inflammatory response
  • toll like receptor
  • coronary artery disease
  • optical coherence tomography
  • coronary artery
  • left ventricular
  • aortic valve
  • data analysis