Extended phase graph formalism for systems with magnetization transfer and exchange.

Shaihan J MalikRui Pedro A G TeixeiraJoseph V Hajnal
Published in: Magnetic resonance in medicine (2017)
The EPG-X framework can be used for modeling both steady-state and transient signal response of systems exhibiting exchange or MT. This may be particularly beneficial for relaxometry approaches that rely on characterizing transient rather than steady-state sequences. Magn Reson Med 80:767-779, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Keyphrases
  • magnetic resonance
  • cerebral ischemia
  • contrast enhanced
  • magnetic resonance imaging
  • convolutional neural network