Evolution and refinement of magnetically guided sentinel lymph node detection in breast cancer: meta-analysis.
Eirini PantioraMarios Konstantinos TasoulisAntonios ValachisStaffan ErikssonThorsten KühnAndreas KarakatsanisIsabel T RubioPublished in: The British journal of surgery (2022)
The performance of SPIO is comparable to that of RI ± BD. Preoperative injection increases the detection rate and nodal yield, without affecting concordance. Whether skin staining and MRI artefacts are reduced by lower dose and peritumoral injection needs to be investigated.