Multi-domain analysis of microvascular flow motion dynamics in NAFLD.
Andrew J ChipperfieldMarjola ThanajEleonora ScorlettiChristopher D ByrneGeraldine F CloughPublished in: Microcirculation (New York, N.Y. : 1994) (2019)
Time and frequency domain measures alone are insufficient to discriminate between groups. As cardiovascular disease risk increases, the degree of complexity of the blood flux signal reduces, indicative of a reduced temporal activity and heterogeneous distribution of blood flow within the microvascular network sampled. Complexity-based methods, particularly multiscale variants, are shown to have good discriminatory capabilities.