Hollow-Core Photonic Crystal Fiber Mach-Zehnder Interferometer for Gas Sensing.
Kaveh NazeriFarid AhmedVahid AhsaniHang-Eun JoeColin BradleyEhsan ToyserkaniMartin Byung-Guk JunPublished in: Sensors (Basel, Switzerland) (2020)
A novel and compact interferometric refractive index (RI) point sensor is developed using hollow-core photonic crystal fiber (HC-PCF) and experimentally demonstrated for high sensitivity detection and measurement of pure gases. To construct the device, the sensing element fiber (HC-PCF) was placed between two single-mode fibers with airgaps at each side. Great measurement repeatability was shown in the cyclic test for the detection of various gases. The RI sensitivity of 4629 nm/RIU was demonstrated in the RI range of 1.0000347-1.000436 for the sensor with an HC-PCF length of 3.3 mm. The sensitivity of the proposed Mach-Zehnder interferometer (MZI) sensor increases when the length of the sensing element decreases. It is shown that response and recovery times of the proposed sensor inversely change with the length of HC-PCF. Besides, spatial frequency analysis for a wide range of air-gaps revealed information on the number and power distribution of modes. It is shown that the power is mainly carried by two dominant modes in the proposed structure. The proposed sensors have the potential to improve current technology's ability to detect and quantify pure gases.