Cryopreservation of ram semen: Manual versus programmable freezing and different lengths of equilibration.

Jakub VozafAlexander V MakarevichAndrej BalaziJaromir VasicekAndrea SvoradovaLucia OlexikovaPeter Chrenek
Published in: Animal science journal = Nihon chikusan Gakkaiho (2022)
The aim of our study was to examine effects of the length of semen equilibration as well as two freezing techniques on ram sperm post-thaw quality. The ejaculates of Wallachian sheep rams (n = 12) were collected by an electro-ejaculation, equilibrated in a Triladyl® (0, 2, 4, 6, and 8 h) containing glycerol and egg yolk and frozen by programmable freezing (PF) or manual freezing (MF). After thawing, sperm samples were subjected to the motility (computer-assisted sperm analysis [CASA]), viability (SYBR-14/PI), and fertilizing ability (FA) (in vitro penetration/fertilization test on bovine oocytes) assays. It was found that the equilibration of 6 h (E-6) ensured higher post-thaw sperm motility and progressive movement compared with other lengths tested, irrespective of a freezing technique. The E-6 sperm viability did not differ between PF and MF but was lower (P < 0.05) than control. Sperm FA (E-6) was similar in PF (60.44%) and MF (62%) but slightly lower than in fresh (72.8%). Our data demonstrate that the use of MF was comparable with PF, which can be applied in the field conditions without need in a piece of cost-expensive equipment, which can greatly benefit the gene bank of animal genetic resources.