Early complications and causes of revision after rotating-hinge TKA.
L RouquetteCécile BataillerB MullerP NeyretE ServienS LustigPublished in: Archives of orthopaedic and trauma surgery (2019)
This rotating-hinge TKA provides satisfying clinical and functional outcomes in primary intentions and in revision cases. There was no implant-associated complication. The complication rate remains high for revision surgery cases, mostly due to previous joint infections and poor soft tissue quality causing extensor mechanism failure. A longer-term study should be conducted to confirm this trend.