Validity of spectral analysis based on heart rate variability from 1-minute or less ECG recordings.

Naomi TakahashiAkira KuriyamaHoshinori KanazawaYoshimitsu TakahashiTakeo Nakayama
Published in: Pacing and clinical electrophysiology : PACE (2018)
Although slight proportional errors were possible, values from standard 5-minute and shorter recordings in the supine position were strongly correlated. Our findings suggest that shorter ECG data without strict preconditioning can be reliably used for spectral analysis.