Login / Signup

Contralateral Routing of Signal Disrupts Monaural Sound Localization.

Sebastian A AusiliHillary A Snapp
Published in: Audiology research (2023)
Results suggest contralateral routing of signal hearing aids disrupt monaural spectral and level cues, which leads to detriments in localization performance in both the horizontal and vertical dimensions. Increased reaction time and increasing variability in responses suggests localization is more effortful when wearing the contralateral rerouting of signal device.
Keyphrases
  • optical coherence tomography
  • antiretroviral therapy
  • magnetic resonance
  • hearing loss