Experimental validation of a mean systemic pressure analog against zero-flow measurements in porcine VA-ECMO.
Per Werner MollerPaul Philipp HeinischAnisa HanaKaspar F BachmannSoren SondergaardStephan M JakobJukka TakalaDavid C BergerPublished in: Journal of applied physiology (Bethesda, Md. : 1985) (2022)
The mean systemic pressure analog (Pmsa), calculated from running hemodynamic data, estimates mean systemic filling pressure (MSFP). This post hoc study used data from a porcine veno-arterial extracorporeal membrane oxygenation (ECMO) model [ n = 9; Sus scrofa domesticus ; ES breed (Schweizer Edelschwein)] with eight experimental conditions; Euvolemia [a volume state where ECMO flow produced normal mixed venous saturation (S V O 2 ) without vascular collapse]; three levels of increasing norepinephrine infusion (Vasoconstriction 1-3); status after stopping norepinephrine (Post Vasoconstriction); and three steps of volume expansion (10 mL/kg crystalloid bolus) (Volume Expansion 1-3). In each condition, Pmsa and a "reduced-pump-speed-Pmsa" (Pmsa red ) were calculated from baseline and briefly reduced pump speeds, respectively. We calculated agreement for absolute values (per condition) and changes (between consecutive conditions) of Pmsa and Pmsa red , against MSFP at zero ECMO flow. Euvolemia venous return driving pressure was 5.1 ± 2.0 mmHg. Bland-Altman analysis for Pmsa vs. MSFP (all conditions; 72 data pairs) showed bias (confidence interval) 0.5 (0.1-0.9) mmHg; limits of agreement (LoA) -2.7 to 3.8 mmHg. Bias for ΔPmsa vs. ΔMSFP (63 data pairs): 0.2 (-0.2 to 0.6) mmHg, LoA -3.2 to 3.6 mmHg. Bias for Pmsa red vs. MSFP (72 data pairs): 0.0 (-0.3 to -0.3) mmHg; LoA -2.3 to 2.4 mmHg. Bias for ΔPmsa red vs. ΔMSFP (63 data pairs) was 0.2 (-0.1 to 0.4) mmHg; LoA -1.8 to 2.1 mmHg. In conclusion, during veno-arterial ECMO, under clinically relevant levels of vasoconstriction and volume expansion, Pmsa accurately estimated absolute and changing values of MSFP, with low between-method precision. The within-method precision of Pmsa was excellent, with a least significant change of 0.15 mmHg. NEW & NOTEWORTHY This is the first study ever to validate the mean systemic pressure analog (Pmsa) against the reference mean systemic filling pressure (MSFP) determined at full arterio-venous pressure equilibrium. Using a porcine ECMO model with clinically relevant levels of vasoconstriction and volume expansion, we showed that Pmsa accurately estimated absolute and changing values of MSFP, with a poor between-method precision. The within-method precision of Pmsa was excellent.