Login / Signup

Horror of three synergistic factors in THA: high mechanical stress, dissimilar metals, low elasticity stem: a case report.

Seiya IshiiYasuhiro HommaTakehisa MatsukawaTomonori BabaAyano KubotaKazuhito YokoyamaKazuo KanekoMuneaki Ishijima
Published in: Arthroplasty (London, England) (2021)
Stem dissociation in the present case might have been caused by synergistic combination of a 36-mm-diameter femoral head and long neck length offset with high frictional torque, a cobalt-chromium head with a high risk of galvanic corrosion, and a TMZF (TiMo12Zr6Fe2) alloy stem with a low Young's modulus of elasticity. The combination of these factors must be avoided.