Role of DOAC plasma concentration on perioperative blood loss and transfusion requirements in patients with hip fractures.

Hannah HoferDaniel OberladstätterChristoph J SchlimpWolfgang VoelckelJohannes ZipperleChris LockieOliver GrottkeMarcin OsuchowskiHerbert Schöchl
Published in: European journal of trauma and emergency surgery : official publication of the European Trauma Society (2022)
No strong association between the DOAC plasma levels and perioperative blood loss was detected. Higher transfusion rates in patients with DOAC levels ≥ 80 ng/mL were primarily related to lower admission haemoglobin levels. DOAC concentration measurement is feasible and expedites time to surgery.