Pattern of pressure gradient alterations after venous sinus stenting for idiopathic intracranial hypertension predicts stent-adjacent stenosis: a proposed classification system.
Daniel M S RaperThomas J BuellDale DingChing-Jen ChenRobert M StarkeKenneth C LiuPublished in: Journal of neurointerventional surgery (2017)
The pattern of change in the trans-stenosis venous pressure gradient may be predictive of SAS and is a useful tool for classifying the response of the venous obstruction to stenting. A type I pattern appears to represent the ideal response to VSS. Some patients with type II and III changes, particularly if they have other predictors of recurrent stenosis, may benefit from longer initial stent constructs.