Ultrasound attenuation of cortical bone correlates with biomechanical, microstructural, and compositional properties.
Saeed JerbanVictor BarrereBehnam NamiranianYuanshan WuSalem AleneziErik DortheDarryl DlimaSameer B ShahChristine B ChungJiang DuMichael P AndreEric Y ChangPublished in: European radiology experimental (2024)
• Ultrasound attenuation demonstrated significant positive correlations with bone mechanics and mineral density. • Ultrasound attenuation demonstrated significant negative correlations with porosity and bone water contents. • This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone.