PROTECT: PRoximal balloon Occlusion TogEther with direCt Thrombus aspiration during stent retriever thrombectomy - evaluation of a double embolic protection approach in endovascular stroke treatment.

Christian MaegerleinSebastian MönchTobias Boeckh-BehrensManuel LehmDennis M HedderichMaria Teresa BerndtSilke WunderlichClaus ZimmerJohannes KaesmacherBenjamin Friedrich
Published in: Journal of neurointerventional surgery (2017)
The PROTECT technique is a promising new approach to significantly reduce thrombus fragmentation and, hence distal embolization during MT. This safe and efficient technique needs to be validated in larger trials to confirm our results.