3D printed implant surgical guides with internally routed irrigation for temperature reduction during osteotomy preparation: A pilot study.
Sorin Theodor TeichMichael BockletZachary EvansZvi GutmacherWalter G RennePublished in: Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] (2021)
The in-vitro analysis shows that this method can significantly mitigate the temperature increase caused by static surgical guide irrigation blockade at the osteotomy site. This technique also has the advantage that it can be incorporated in the digital surgical guide design using commercially available software and 3D printing technology. The method has immediate applications in practice, and especially in the treatment of edentulism in esthetic zone where use of guided surgery for implant placement is crucial in obtaining consistent results.