Simplified image-based dosimetry using planar images and patient-specific S-values.

Keon Min KimMinseok SuhGi Jeong CheonMin Sun LeeJae Sung Lee
Published in: Medical physics (2024)
As the PSS was derived using CT images with actual anatomical information and organ-specific volume of interest (VOI), PSS dosimetry provided reliable results. PSS dosimetry was robust in estimating the absorbed dose for the later treatment cycles. Therefore, PSS dosimetry outperformed hybrid dosimetry in terms of dose estimation for a greater number of treatment cycles.