Login / Signup

Volumetric surveillance of brain aneurysms: Pitfalls of MRA.

Ashrita RaghuramRishi PatelAlberto VaronRyan SabotinSebastian SanchezColin P DerdeynPascal JabbourDavid M HasanEdgar A Samaniego
Published in: Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences (2022)
CE-MRA and TOF-MRA 3D volume reconstructions may not register minor morphological changes such as the appearance of blebs. CE-MRA underestimates volume by 7.8% compared to 3DRA. Serial CE-MRA volume measurements had a larger margin of error of approximately 10.2%. MRA-based volumetric measurements may not be appropriate for aneurysm surveillance.
Keyphrases
  • contrast enhanced
  • magnetic resonance imaging
  • public health
  • computed tomography
  • magnetic resonance
  • mass spectrometry
  • coronary artery
  • resting state
  • brain injury
  • dual energy