Utilizing nasal-tragus length to estimate optimal endotracheal tube depth in neonates: A prospective randomized control study.
Anjusha Thazhe VeettilCharu BambaVanya ChughPublished in: Paediatric anaesthesia (2022)
Based on the results from the studied sample, NTL +1 cm formula is a better predictor than Weight + 6 cm formula to determine endotracheal tube insertion depth in term Indian neonates.