ANTEGRADE NAILING VERSUS LOCKING PLATE OF 2-AND 3-PART PROXIMAL HUMERUS FRACTURES.
Gustavo Remigio GomesRafael Almeida MacielJosé Inácio DE Almeida NetoDaniel Carvalho DE ToledoCarla Jorge MachadoLeonidas DE Souza BomfimPublished in: Acta ortopedica brasileira (2022)
Osteosynthesis, with a locking plate and antegrade nailing, did not show differences in the proportion of complications. The nail group had less change in the postoperative cervicodiaphyseal angle, however, there were two serious complications with screw cut-out and varus deviation, requiring surgical reapproach.