Prospective randomized clinical trial evaluating efficacy and safety of a new ophthalmic viscosurgical device in patients undergoing cataract surgery.

Luigi De RosaLuca FuriosiMarco PellegriniAngeli Christy YuVincenzo ScorciaMassimo Busin
Published in: Journal of cataract and refractive surgery (2024)
Bio-Hyalur LVD OVD was safe and effective in patients undergoing routine cataract surgery. Bio-Hyalur LVD OVD did not confer a higher risk of postoperative increase in IOP.
Keyphrases
  • cataract surgery
  • patients undergoing
  • clinical practice