Login / Signup

Effect of 808 nm Semiconductor Laser on the Stability of Orthodontic Micro-Implants: A Split-Mouth Study.

Jacek MatysRafał FliegerTomasz GedrangeKrzysztof JanowiczBartosz KempistyKinga Grzech-LeśniakMarzena Dominiak
Published in: Materials (Basel, Switzerland) (2020)
Patients did not report significant differences in terms of pain experiences comparing the L and C groups (p = 0.499). At 30 days post-treatment, higher secondary stability of implants was observed in the laser group (Periotest Test Value, PTV 6.32 ± 3.62), in contrast to the controls (PTV 11.34 ± 5.76) (p = 0.004). At 60 days post-treatment, significantly higher stability was recorded in the laser group (PTV 6.55 ± 4.66) compared with the controls, PTV (10.95 ± 4.77) (p = 0.009). Conclusions: Application of the 808 nm diode laser increased secondary micro-implant stability.
Keyphrases