False lumen/true lumen wall pressure ratio is increased in acute non-A non-B aortic dissection.
Naoyuki KimuraMasanori NakamuraReiya TakagiMakiko Naka MienoAtsushi YamaguchiMartin CzernyFriedhelm BeyersdorfFabian Alexander KariBartosz RylskiPublished in: Interactive cardiovascular and thoracic surgery (2022)
The increased FL/TL wall pressure ratio observed during systole in non-A non-B AD may beget a complicated presentation.