Influence of different drilling preparation on cortical bone: A biomechanical, histological, and micro-CT study on sheep.
Michele StoccheroMarco ToiaYohei JinnoFrancesca CecchinatoJonas P BecktorYoshihito NaitoAnders HalldinRyo JimboPublished in: Clinical oral implants research (2018)
Implants inserted into undersized sites has an increased biomechanical performance, but provoked major remodeling of the cortical bone during the early healing period compared to non-undersized preparations. After 10 weeks, no difference was observed.