Double scleral tunnel technique to prevent glaucoma drainage device exposure.
Eamonn T FahyAnurag GargKin Sheng LimPublished in: European journal of ophthalmology (2023)
This double scleral tunnel technique to secure the GDD silicone tubing firmly to the sclera may reduce micro-movements which have been purported to be associated with tissue erosion post GDD surgery. The addition of this simple technique to existing GDD surgery may reduce the risk of post-operative tube exposure.