Bacterial screening of apheresis platelets with a rapid test: a 113-month single center experience.

Kristen N RubyReggie R ThomassonZbigniew M SzczepiorkowskiNancy M Dunbar
Published in: Transfusion (2018)
To date, we have not detected any true positives after performing 11,306 tests on 9009 APs. A total of 1906 underwent testing twice, and 391 underwent testing three times. We did not identify any conversions from negative to positive on repeat testing.
Keyphrases