Analysis of laboratory parameters for optimal autologous peripheral blood stem cell collection from lymphoma and myeloma patients.
Jung Hee KongYoumi HuSun-Young KongSe-Na LeeHyeon-Seok EomHyewon LeeEunyoung LeeHyoeun ShimPublished in: Journal of clinical apheresis (2020)
HPC count is a potential surrogate marker for monitoring the starting time for PBSC collection. Applying cutoff values for the number of HPC and CD34+ cells may be clinically useful for optimizing the timing of PBSC collection.