Login / Signup

Stensen's Duct Dynamic Anatomy Assessed with Sialography.

Piper A WenzelRyan Kendall ThorpeJoan E MaleyBruno A PoliceniReinhard R BeichelKailey D HenkleHenry T Hoffman
Published in: Ear, nose, & throat journal (2024)
Objectives: The presence of a catheter required for contrast infusion during sialography obscures imaging of the distal duct. Static imaging via cone beam computed tomography and magnetic resonance sialography fails to address changes that occur dynamically to the anatomy of the flexible salivary ductal system. We aim to identify dynamic changes to the parotid gland by introducing a novel approach to analyze the full extent of Stensen's duct based on dynamic infusion digital sialography. Methods: Retrospective chart review of a single-center consecutive series of 409 parotid sialograms performed between April 2008 and June 2023 permitted selection of a contemporary series including seven normal sialograms and seven sialograms with stricture(s). Dynamic (fluoroscopic) infusion (iopamidol/gadolinium) sialograms were assessed through blinded review by two radiologists employing the institution's picture archiving and communication (PACS) system (©2023 Koninklijke Philips N.V., Amsterdam, Netherlands). Measurements determined changes, in two dimensions, to the angle of the masseteric bend and duct length while the catheter was in place (repose), during catheter withdrawal (stretch), and during recoil after withdrawal. Differences in median lengths and angles of Stensen's duct between the three time points were compared using Wilcoxon matched-pairs signed rank and Mann-Whitney tests. Results: Fourteen patients [median age (IQR), 55 years (24.7); 10 women] were evaluated. The median angle of the masseteric bend was 117.7° in repose versus 155.4° during catheter withdrawal ( P < .001, n = 14). The median distance measured from the Stensen's duct orifice to the first major ductal bifurcation was 81.5 mm (IQR = 12.3) in repose. The median percent increase in length from repose to stretch was 6.3% ( P < .001, n = 14). Conclusions: Dynamic infusion digital sialography with fluoroscopic recording during catheter removal permits assessment of the distal duct unobstructed by the presence of a catheter. The technique also identifies the dynamic nature and varying length and angulation of Stensen's duct.
Keyphrases