Inter-leg systolic blood pressure difference predicts cardiovascular events and mortality in incident hemodialysis patients.
Sawako KatoBengt LindholmAbdul Rashid QureshiHideyuki MukaiYukio YuzawaShoichi MaruyamaPublished in: The International journal of artificial organs (2019)
Higher inter-leg systolic blood pressure difference associated with increased risk of mortality and cardiovascular events suggesting that wider application of inter-leg systolic blood pressure difference measurements may be warranted in hemodialysis patients.