Frequency of Optical Coherence Tomography Testing to Detect Progression in Glaucoma.
Bruna MelchiorCarlos G De MoraesJayter S PaulaGeorge A CioffiChristopher A GirkinMassimo A FazioRobert N WeinrebLinda M ZangwillJeffrey M LiebmannPublished in: Journal of glaucoma (2022)
With high specificity and less variability than perimetry, a 6-month testing interval provides a reasonable trade-off for following glaucoma patients using OCT.