Login / Signup

Safety of maximal cardiopulmonary exercise testing in individuals with sickle cell disease: a systematic review.

Kellsey N SmithTracy BaynardPeter S FischbachJane S HankinsLewis L HsuPeggy M MurphyKiri K NessShlomit Radom-AizikAmy TangRobert I Liem
Published in: British journal of sports medicine (2021)
Maximal CPET appears to be a safe testing modality in children and adults with SCD and can be used to better understand the physiological basis of reduced exercise capacity and guide exercise prescription in this population. Some studies did not focus on reporting adverse events related to exercise testing or failed to mention safety monitoring, which contributed to risk of bias.