Recurrent laryngeal nerve monitoring during totally robot-assisted Ivor Lewis esophagectomy.
J I StaubitzP C van der SluisF BerlthF WatzkaF DetteA LäßigH LangT J MusholtPeter Philipp GrimmingerPublished in: Langenbeck's archives of surgery (2020)
IONM was feasible during RAMIE. The intraoperative identification of the RLN location contributed to the accuracy of lymph node dissection of the paratracheal lymph node stations. RLN damage and subsequent postoperative vocal cord paresis can potentially be prevented by IONM.