Percutaneous Edge-to-Edge Tricuspid Valve Repair in a Patient with Cor Triatriatum Dexter: A Case Report.
Fabian BarbieriMark SchröderNiklas BeyhoffUlf LandmesserMarkus ReinthalerMario KasnerPublished in: Journal of cardiovascular development and disease (2021)
Our case highlights the feasibility of percutaneous edge-to-edge tricuspid valve repair in an elderly woman with cor triatriatum dexter. Accurate echocardiographic visualization is an absolute requirement to gain access to the tricuspid valve without interacting with prevailing additional membranes.