Three-dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification.

Abdallah El SabbaghMackram F EleidJane M MatsumotoNandan S AnavekarMohammed A Al-HijjiSameh M SaidVuyisile T NkomoDavid R HolmesCharanjit S RihalThomas A Foley
Published in: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2018)
3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction.