Radiation exposure of image-guided intrathecal administration of nusinersen to adult patients with spinal muscular atrophy.

Denise BosN GuberinaB StolteK KizinaE StenzelA RadbruchC KleinschnitzT HagenackerM ForstingC Mönninghoff
Published in: Neuroradiology (2019)
Radiation exposure of SMA patients measured as DRLs is generally not higher compared with patients without SMA despite severe anatomical hazards. Dose monitoring data may allow clinicians to stratify radiation risk, identify organs at risk, and adopt measures for specific radiation dose reduction.