Open-sleeve templates for computer-assisted implant surgery at healed or extraction sockets: An in vitro comparison to closed-sleeve guided system and free-hand approach.
Junying LiPriscila Ceolin MeneghettiMatthew GalliGustavo MendoncaZhaozhao ChenHom-Lay WangPublished in: Clinical oral implants research (2022)
In this in vitro investigation, open-sleeve sCAIS proved better accuracy than free-hand surgery for both delayed and immediate implant placement. Compared with a closed-sleeve sCAIS system, open sleeve have the potential of providing better outcomes in extraction sockets but not in healed sites.